• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Journal of Advanced Biomedical and Pharmaceutical Sciences
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 8 (2025)
Volume Volume 7 (2024)
Volume Volume 6 (2023)
Volume Volume 5 (2022)
Volume Volume 4 (2021)
Volume Volume 3 (2020)
Issue Issue 4
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 2 (2019)
Volume Volume 1 (2018)
Rashed, A., Hetta, A., Hashem, Z., El-Katatny, M. (2020). Validation of moist and dry heat processes used for sterilization and depyrogenation during ampoules manufacturing. Journal of Advanced Biomedical and Pharmaceutical Sciences, 3(3), 177-183. doi: 10.21608/jabps.2020.27282.1083
Ahmed M. Rashed; Ahmed M.A. Hetta; Zeinab S. Hashem; Mo'men H. El-Katatny. "Validation of moist and dry heat processes used for sterilization and depyrogenation during ampoules manufacturing". Journal of Advanced Biomedical and Pharmaceutical Sciences, 3, 3, 2020, 177-183. doi: 10.21608/jabps.2020.27282.1083
Rashed, A., Hetta, A., Hashem, Z., El-Katatny, M. (2020). 'Validation of moist and dry heat processes used for sterilization and depyrogenation during ampoules manufacturing', Journal of Advanced Biomedical and Pharmaceutical Sciences, 3(3), pp. 177-183. doi: 10.21608/jabps.2020.27282.1083
Rashed, A., Hetta, A., Hashem, Z., El-Katatny, M. Validation of moist and dry heat processes used for sterilization and depyrogenation during ampoules manufacturing. Journal of Advanced Biomedical and Pharmaceutical Sciences, 2020; 3(3): 177-183. doi: 10.21608/jabps.2020.27282.1083

Validation of moist and dry heat processes used for sterilization and depyrogenation during ampoules manufacturing

Article 5, Volume 3, Issue 3, July 2020, Page 177-183  XML PDF (703.87 K)
Document Type: Original Article
DOI: 10.21608/jabps.2020.27282.1083
View on SCiNiTO View on SCiNiTO
Authors
Ahmed M. Rashed1; Ahmed M.A. Hetta2; Zeinab S. Hashem3; Mo'men H. El-Katatny email 2
1Ultimate pharma Company, Alexandria, Egypt
2Department of Botany and Microbiology, Faculty of Science, Minia University, 61519 Minia, Egypt
3Department of Microbiology and Immunology, Faculty of Pharmacy, Minia University, 61519 Minia, Egypt
Abstract
Pyrogens are fever-producing substances, which are metabolic products of microorganisms and most potent pyrogens are the endotoxins. Depyrogenation can be defined as the elimination of all pyrogenic substances which is an important part of the manufacture of sterile pyrogen free pharmaceutical products. This study compared between sterilization and depyrogenation using moist heat by autoclave, as well as dry heat. After incubation period (24 hours) at 55oC-60oC the color of Geobacillus stearothermophillus spores’ control vial which didn’t sterilized in autoclave changed from blue to yellow color representing the (+ve) result, while the other sterilized vials have no color change (-ve). In addition, all examined endotoxin containing ampoules showed gel formation (+ve) when examined by Limulus Amebocyte Lysate) LAL). All ampoule groups that have autoclaved for periods of 1 hour to 4 hours showed gel formation (+ve) after LAL test, while only the last group which have autoclaving periods of 5 hours (5 cycles) showed no gel formation (-ve). Sterility of vials that contained spores of Geobacillus stearothermophillus after dry heating at 250oC for 30 min showed no color change (-ve). In addition, LAL test for endotoxin containing ampoules after dry heating at 250oC for 30 min showed no gel formation representing -ve pyrogen. So, moist heat is effective in sterilization and not for depydrogenation, whereas, dry heat is effective in sterilization as well as for depyrogenation.
Keywords
Sterilization; Dry and moist heat; Depyrogenation; Ampoule; Endotoxin
Main Subjects
Pharmaceutics
Statistics
Article View: 2,858
PDF Download: 9,070